News Release

Ultrasound Method Diagnoses Stress Before Bridges Crack

Peer-Reviewed Publication

National Institute of Standards and Technology (NIST)

NIST scientists are using ultrasound to measure the change in stresses on pin and hanger assemblies found on bridges. Their goal is to develop a method for assessing the status of these connections.

In a typical situation, a pin and hanger connection is used to suspend an inner span from an outer support span; it also accommodates thermal expansion. But because the connection is located at the expansion joint, road deicing salts may wash down through the joint and cause corrosion at the pins. If the corrosion is sufficient to lock up the pins, it can cause additional forces on the connection, leading to fatigue cracking and eventual failure.

NIST is experimenting with an ultrasound technique, which has the potential to determine connection stress prior to development of fatigue cracks. To evaluate its method, NIST designed and constructed a pin and hanger simulation facility at its Boulder, Colo., laboratories. Strain gauges were mounted on the hangers, and the strains were measured as load was applied. At the same time, ultrasonic measurements were made at the gauge locations.

Strains were predicted from the ultrasonic data and compared with values measured by the strain gauges. "Overall good agreement was obtained between ultrasonic and strain gauge results," the scientists report.

For technical paper no. 13-98, which describes the work, contact Sarabeth Harris, MS104, NIST, Boulder, Colo. 80303-3328, (303) 497-3237.

###



Disclaimer: AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert system.