News Release

Peering into tissue stiffness with VIPA-based Brillouin spectroscopy

Researchers at the University of Maryland have developed a novel spectroscopy configuration that can obtain a sample's entire Brillouin spectrum in one shot - saving time and allowing for noninvasive biological characterization

Peer-Reviewed Publication

American Institute of Physics

All-Optical Mechanical Measurement of Tissue

image: TOP: Intralipid solutions of 0%, 0.01%, 0.1%, 1%, 10% and 20% concentrations; the new three stage spectrometer can suppress the background light of up to a 5% Intralipid solution with a total loss of over 90%. BOTTOM: The signal to background ratio of Brillouin spectra for the concentrations. view more 

Credit: G. Scarcelli/UMD

Washington, D.C., May 17, 2016 -- At a microscopic level, every material contains spontaneous sound waves -- acoustic phonons -- that have properties dependent on the material's mechanical properties. When light interacts with these acoustic phonons, it scatters and acquires a frequency shift related to the material's elastic modulus, a characteristic measure of its ability to resist deformation and stress.

A technique known as Brillouin spectroscopy works by measuring this frequency shift, and has been an effective tool for noninvasively examining materials for several decades. The technique, however, necessitates scanning interferometers, which are low-throughput and result in long data acquisition times.

To bring this method to biological samples -- such as a chicken breast, or a patient's potentially cancerous tumor -- researchers at the University of Maryland and Harvard Medical School have recently developed a new virtually imaged phased array-based Brillouin spectrometer. They describe their new interferometer configuration this week in Applied Physics Letters, from AIP Publishing.

"We have been developing this new VIPA-based Brillouin spectrometer for a long time. In this paper, we added a multi-pass low-finesse Fabry-Perot interferometer, which works as a tunable and narrowband filter," said Giuliano Scarcelli, an assistant professor in the Fischell Department of Bioengineering at the University of Maryland.

While past development of virtually imaged phased array-based spectrometers allowed the researchers to collect the entire Brillouin spectrum in a single shot, saving processing time and power, the design could only interrogate transparent materials such as ocular tissue or cells because turbid media generate too much unwanted light noise for the spectrometer to handle.

By adding a triple-pass Fabry-Perot filter, the researchers were able to increase the spectrometer's ability to suppress such unwanted light component by more than tenfold, allowing them to measure background-free spectra up to 100 micrometers deep within a sample of chicken tissue.

Future work for Scarcelli and his colleagues includes improving Brillouin technology to measure spectra faster, with greater sensitivity and at higher spatial resolution, as well as expanding characterization to include tumors, atherosclerotic plaques and brain tissue.

###

The article, "High-extinction VIPA-based Brillouin spectroscopy of turbid biological media," is authored by Antonio Fiore, Jitao Zhang, Peng Shao, Seok Hyun Yun and Giuliano Scarcelli. It published in the journal Applied Physics Letters on May 17, 2016 (DOI: 10.1063/1.4948353) and can be accessed at http://scitation.aip.org/content/aip/journal/apl/108/20/10.1063/1.4948353.

ABOUT THE JOURNAL

Applied Physics Letters features concise, rapid reports on significant new findings in applied physics. The journal covers new experimental and theoretical research on applications of physics phenomena related to all branches of science, engineering, and modern technology. See http://apl.aip.org.


Disclaimer: AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert system.