Cardiac arrest in space: New research shows that automatic chest compressions are more effective for CPR when both rescuer and patient are floating in microgravity

Reports and Proceedings

European Society of Cardiology

Key take-aways

  • New research has found that a type of automatic chest compression is more effective to carry out CPR in space than the ‘handstand method’ that is currently recommended in emergency protocols for spaceflight. Treating cardiac arrest during spaceflight is challenging because both the rescuer and the patient are floating due to microgravity, which makes doing chest compressions challenging. 

  • The research was conducted in a ‘flying laboratory’ in a modified A310 aircraft at the CNES (French space agency). Freefalling phases of parabolic flight were used to accurately recreate microgravity so CPR could be tested by researchers on a floating mannikin. 

  • The researchers say they hope their findings will influence future guidelines (1) about CPR in space. They suggest that space agencies will need to balance risks from cardiac arrest against space and weight constraints when deciding whether to include automatic chest compression devices on future spaceflights. 

Madrid, Spain – 27 August 2025: New research has found a more effective way to conduct cardiopulmonary resuscitation (CPR) in microgravity,* which causes the weightlessness astronauts experience in space.  

The study found that a type of automatic chest compression, carried out by a standard mechanical piston device, reached the depth needed to be effective, while the current CPR methods recommended for space travel are undereffective regarding this depth criteria.  

Treating cardiac arrest during spaceflight is challenging because both the rescuer and the patient are floating due to microgravity. The current NASA emergency protocol for the International Space Station recommends the hand-stand method of CPR, where the rescuer performs a handstand on the patient’s chest with their legs pressing on the side of the spaceship to create the pressure needed for chest compressions.  

“We tested different ways of giving chest compressions aboard a ‘flying laboratory’ which recreated the microgravity conditions that astronauts experience in space. Use of a particular type of automatic chest compression device was the only method that gave the depth that is recommended by international resuscitation guidelines to keep blood flowing to the brain in a real life cardiac arrest. We hope that our findings will be incorporated into the next guidelines (1) for treating cardiac arrest in space,” Explained Nathan Reynette from the Cardiology Department at Université de Lorraine – CHRU de Nancy. 

The research was conducted in a ‘flying laboratory’ onboard a modified civil aircraft, the only one of its kind in Europe, called the A310 Air Zero G at the Centre National d'Etudes Spatiales, the French space agency. Freefalling phases of parabolic flight were used to accurately recreate microgravity for 22 seconds during each parabola, with around 30 parabolas per single fight. The experiments were conducted over three flights. Chest compression depths and rates were monitored by a high fidelity CPR training manikin. 

Earth-based chest compressions during CPR are based on the rescuer’s weight, which does not exist in microgravity. As a result, over the last 30 years, researchers have searched for alternative methods, such as the Handstand method, Reverse Bear Hug method and the Evetts Russomano method. Until now, despite numerous trials, none of the proposed methods were shown to reach the depth standards needed for effective chest compressions.  

Three types of automatic chest compression devices were tested. Automatic chest compression devices are routinely used on Earth by doctors in restricted environments such as emergency helicopter, or where prolonged CPR needs to be carried out over a longer period of time, such as refractory cardiac arrest which can last for more than 40 minutes. This type of CPR is not considered to be superior to manual CPR in normal conditions but has been proven to be effective when chest compressions are challenging.  

Three types of automatic chest compression devices were tested;  a standard mechanical piston device, a compression band device, and a small-sized piston device.  Best practice guidance, such as advice given by the European Resuscitation Council (2), suggests that to be effective chest compressions must reach a depth of between 50 to 60mm.  

Of the three automatic chest compression devices tested, the standard mechanical piston device had the highest median compression depth. The median compression depth of the standard mechanical piston device was 53.0mm, which was considerably more than the other two automatic chest compression devices, that both had median depths of 29mm, and the manual handstand method of CPR which achieved a depth of 34.5mm. 

Reflecting on whether future space missions will take automatic chest compression devices in their emergency medical kit, Mr Reynette said, “It will be up to every space agency whether they want to include automatic chest compression devices in their emergency medical kit. We know they have other considerations beyond effectiveness, such as weight and space constraints.   

“While cardiac arrest is a high danger event, that could even terminate a space mission, it is a relatively low risk for now. Most astronauts are young, healthy and physically fit individuals who have intensive medical monitoring, including scanning for chronic heart disease, before going into space. Nevertheless, longer lasting space missions in future and space tourism could increase the risks of a medical emergency occurring.” He continued. 

The research project was a collaboration between clinicians from the CHU de Nancy, medical researchers from University of Lorraine and University of Paris, engineers from the Laboratoire Georges Charpak of the Ecole Nationale des Arts et Metiers Paris Tech and from the Centre National d'Etudes Spatiales, the French space agency and Novespace.  

“This research highlights once again the usefulness of automated chest compression devices to perform CPR in challenging environments. Space medicine often provides transferable lessons for emergency procedures in isolated environments on Earth, where space and clinical experience are also limited. Further research could explore whether automated chest compression devices could prove useful to carry out CPR in environments such as submarines and artic bases.”  Mr Reynette concluded. 

 

ENDS 

 

Notes to editor 

This press release accompanies an abstract at ESC Congress 2025.  

It does not necessarily reflect the opinion of the European Society of Cardiology. 

Funding: The study was supported and funded by the Centre National d’Etudes 

Spatiales, French Space Agency  

 

Disclosures : Authors reports no disclosures 

 

References and notes : 

 

*Microgravity is the condition in which people or objects appear to be weightless in space. It is popularly known as zero gravity, however technically in space very small gravitational forces still exist, so the term microgravity is more accurate.  

 

  1. German Society of Aerospace Medicine (DGLRM) and the European Society of Aerospace Medicine Space Medicine Group (ESAM-SMG) guidance on CPR in space: https://pubmed.ncbi.nlm.nih.gov/33138865/ 

  1. https://pubmed.ncbi.nlm.nih.gov/33773835/  

 

The abstract « Cardiac arrest in space : how to perform cardiopulmonary resuscitation during spaceflight? » will be presented at the session Management of out-of-hospital cardiac arrest which takes place on 31 August from 10:15 to 11:00 am CEST at Station 5 - Research Gateway 

 

 

ESC Press Office  
Tel: +33 661401884    
Email: press@escardio.org   

The hashtag for ESC Congress 2025 is #ESCCongress  

Follow us on LinkedIn @European Society of Cardiology News 

Journalists are invited to become accredited and register here

Check out the ESC Media and Embargo Policy

About ESC Congress 2025 

It is the world’s largest gathering of cardiovascular professionals, disseminating ground-breaking science both onsite in Madrid and online – from 29 August to 1 September 2025. Explore the scientific programme. More information is available from the ESC Press Office at press@escardio.org

About the European Society of Cardiology 

The ESC brings together healthcare professionals from more than 150 countries, working to advance cardiovascular medicine and help people to live longer, healthier lives. 


Disclaimer: AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert system.