News Release

Size of X-Ray beams successfully evaluated with mathematics

Uniform evaluation method for X-ray beam size expected to be widely adopted

Peer-Reviewed Publication

Osaka Metropolitan University

A schematic of the beam diameter measurement using transmitted X-rays old and new methods

image: X-ray beam diameter can be calculated more accurately with the new evaluation method than with conventional methods used previously. The new method shows the same X-ray beam diameter, which remained consistent during this test, when using different wires with variable thickness. view more 

Credit: Kouichi Tsuji, Osaka Metropolitan University

X-ray fluorescence analysis allows elemental analysis in a variety of environments without destroying the sample. The smaller diameter of the X-ray microbeam, the more accurate the elemental distribution can be. Because X-ray beams are not visible, an accurate method is needed to determine beam diameter.

A research group led by Professor Kouichi Tsuji and Specially Appointed Assistant Professor Tsugufumi Matsuyama of the Graduate School of Engineering, and Professor Hideyuki Ishi of the Graduate School of Science, at Osaka Metropolitan University, has developed a new method to evaluate the diameter of X-ray microbeams based on mathematical analysis. While validating the new method, it was found that it can be used to calculate beam diameters more accurately than the previously used conventional methods.

Currently, no uniform evaluation method for X-ray beam diameter has been established. Since this evaluation method was derived using mathematical analysis, it is expected to be widely adopted as an international standard. Potential applications of X-ray fluorescence analysis include materials development, environmental analysis, forensic science, biological sample analysis, and analysis of archaeological and culturally significant objects.

Professor Tsuji concluded, “We hope that this evaluation method will be widely used, and that the establishment of this method of evaluating spatial resolution in X-ray fluorescence will contribute to the development of a wide range of fields, including material development and bio-imaging.”

The research results were published in X-Ray Spectrometry on January 9, 2023.

###

About OMU 

Osaka Metropolitan University is a new public university established by a merger between Osaka City University and Osaka Prefecture University in April 2022. For more science news, see https://www.omu.ac.jp/en/, and follow @OsakaMetUniv_en, or search #OMUScience. 


Disclaimer: AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert system.