image: yz− weighted average of current density (a), temperature (b), and water content (d) across the membrane. Averaged water saturation (c) is reported in between GDLs and membrane. Subplot (e) describes the oxygen concentration average in the GDLc/channel/rib interface. Shaded areas represent half-rib zones. Operating temperature is T0 = 343 K and reactants relative humidity is 90%. view more 

Credit: Universidad de Sevilla

Proton-Exchange Membrane Fuel Cells (PEMFCs), directly converting fuel into electric energy through a solid electrolyte membrane, have become one of the most promising devices in the last few years for the electrical conversion of hydrogen. A team of researchers from the Department of Energy Engineering at the University of Seville together with AICIA (Association for Research and Industrial Cooperation of Andalusia) conducted three-dimensional CFD simulations to analyze the role of water on the performance of a single straight-channel PEMFC under different operating temperatures. The study aimed at gaining further insights into the complex and tightly coupled interactions taking place inside the fuel cell, relating water generation and transport with local temperature distributions and cell performance, with particular emphasis on the under-rib and under-channel features.

A sensitivity analysis has revealed that the higher the operating temperature is, the better the electrical performance of the PEMFC, for the range of operating temperatures in their study (70–90 Cº), as long as the reactants relative humidity is maintained at a high value. Even though the device is operating at high current densities (j = 2.25 and 2.57 A/cm2), the enhancement of the water diffusivity and the electro-osmotic drag resulted in an improvement of the ionic conductivity.

Cross-sectional averages (see IMAGE) concluded that evaporation effects are not so important as to decrease the PEMFC performance under such operating conditions, despite the decrease on the water saturation and membrane hydration levels. On the other hand, temperature profile plots in dimensionless form have exhibited some similarities which might be of interest for the characterization or design of PEMFC via analytical expressions or scaling laws. As for the oxidizer, it has been observed that the distributions of the oxygen consumption look very similar between all the operating temperatures, with the highest values found under-channel and the lowest under-rib, with a clear diminution of the oxygen concentration with the load increase.

Even though an exhaustive sensitivity study was addressed, the researchers claimed that the isolation of a single variable from the rest in a PEMFC is not always possible given the diverse nature and coupling of the processes involved.

This publication has been possible thanks to the grants: Grant PY20 RE 315 026 AICIA funded by S.G. de Universidades, Investigación y Tecnología, PAIDI 2020 program 316 by Junta de Andalucía, co-funded with ERDF funds. Grant PID2019–104441RBI00 funded by 317 MCIN/AEI/10.13039/501100011033, co-funded with ERDF funds.