The total detector efficiency and the efficiencies of individual rings. The detector efficiency curves were simulated by neutron-evaporation spectra and monochromatic neutrons. The red dots are given by the neutron spectrum described by the Maxwell-Boltz (IMAGE)
Caption
Based on the described detector structure, Geant4 simulations were conducted. The total detector efficiency increased from 35.6% at 50 keV to 42.3% at 1.65 MeV for the average neutron energy, then gradually decreased to 40.7% at 3 MeV. Notably, calibration with a 252Cf source yielded an efficiency of 42.1 ± 1.3% at 2.13 MeV, corresponding to the average energy of the 252Cf neutron spectrum, which is marked on the curve.
Credit
Chun-Wang Ma
Usage Restrictions
Credit must be given to the creator. Only noncommercial uses of the work are permitted.
License
CC BY-NC